Use Type EDW Flashing with thick or high profile roofing materials such as concrete tiles, flat tiles, Spanish tiles, corrugated metal and with roof pitches from 15° (3/12) to 85°. Model FS Skylight is shown for illustration purposes. For complete instructions, refer to the instruction sheets provided with the flashing kit. |
1. POSITION SKYLIGHT ON ROOF
Position skylight in roof and attach each premounted bracket with screws provided. Be sure to center the frame in the opening and check corners with framing square. Remove side frame covers and bottom overglass cover. Do not remove the glazing profile.
2. INSTALL ROOFING MATERIAL
Install the roofing material up to the bottom edge of the skylight frame. The sill flashing section must be placed between the underglass rubber gasket and bottom frame section to provide a watertight seal. Push corners of the sill flashing tight against the frame. Attach the sill flashing to the frame with nails provided. Mold sill apron over tiles.
|
 |
3. INSTALL SIDE FLASHING SECTIONS
Attach side flashing to frame with nails provided and to tile battens with clips.
|
 |
4. INSTALL HEAD FLASHING
Interlock head flashing section with the top cover. Attach with screws provided.
Place tiles around the skylight to complete installation.
|
 |